Short answer
An error code names the system that failed: ignition, flame, venting, water flow, a temperature sensor, scale, or the control board. Write the code down exactly, then look it up by brand. Gas, power, water valves, filters and vent terminals are safe to check. Sensor, gas valve, fan or board codes, or any code that returns, need a pro.
Key facts
- Ignition failure is code 11 on Rinnai and Rheem tankless units and E003 on Navien NPE-2 units.[1]
- Navien's NPE-2 manual lists E407 as the hot water outlet sensor fault and E515 as a main circuit board fault, though several websites list E515 as the sensor.[2]
- Rinnai's LC code warns of scale buildup and is the only Rinnai code that lets the unit keep running.[1]
Before you look anything up
If you smell gas, ignore the code. Leave on foot, avoid anything that can spark, and call the gas utility and 911 from a safe place[4].
Otherwise:
- Write the code down exactly, including letters and any number that flashes before or after it.
- Note the model number from the rating label. Some codes mean different things on different families within one brand.
- Note what was happening: a cold snap, a power outage, the furnace running, a new install.
- Do not reset more than once. One power cycle is a reasonable test.
Brand tables
| Brand | Covers | Source document |
|---|---|---|
| Rinnai | SENSEI (RX, CX, RE, RSC), non-SENSEI (V, RL, RU, RUR, RUC), RH180 hybrid | Rinnai diagnostic code guide[1] |
| Navien | NPE-2 condensing tankless (A2 and S2 models) | Navien NPE-2 user's manual[2] |
| Rheem | Rheem and Ruud gas tankless, condensing and non-condensing | Rheem SVC820 pocket manual[3] |
More brands, including A.O. Smith, Noritz, Takagi and the blinking status lights on gas tank heaters, are on our list to add.
The same fault across brands
Different makers, same problems. This cross-reference covers the faults behind most calls:
| Fault | Rinnai[1] | Navien NPE-2[2] | Rheem[3] | Safe check |
|---|---|---|---|---|
| Burner will not light | 11 | E003 | 11 | Gas valve open; other gas appliances work |
| Flame lost after lighting | 12 | E012 | 12 | Confirm gas supply; note other appliances running |
| Vent or air blocked | 10 | E110 | 10, 90, 99 | Clear outside terminals of snow, leaves, nests |
| Overheat | 14 | E016, E030, E046 | 14, 15 | Stop resetting; call a pro |
| Condensate backup | 25 | n/a | 29, 92, 93 | Check the condensate line for clogs or ice |
| Scale or service due | LC, SS | E760 | 1L | Schedule a flush |
| Temperature sensor | 32, 33, 51 and others | E407, E421, E432, E441 | 31 to 34 | None: pro only |
| Fan or blower | 61 | E109 | 61, 79 | Navien: clean intake air filter; otherwise pro |
| Circuit board or control | 70 | E515 | 82 | One power cycle; then pro |
Meanings are our paraphrase. Your model's manual is the final reference.
Myth: Navien E515 is the outlet temperature sensor
Several repair websites say so. Navien's own NPE-2 manual assigns the hot water outlet sensor to E407 and lists E515 as a main circuit board fault[2]. Those are very different repairs at very different prices, so check the manual for your model before ordering parts.
What homeowners can safely check
The makers' documents limit owner checks to things that need no tools and no opening of sealed panels[1][2][3]:
- Gas: the valve to the unit is open, the gas service is on, the propane tank is not empty.
- Power: the unit is plugged in and the breaker is on.
- Water: the cold supply valve is open; the inlet water filter is clean.
- Air (Navien): the intake air filter is clean.
- Vents: the outside intake and exhaust terminals are clear.
- Condensate: the drain line is not kinked, clogged or frozen.
What needs a licensed pro
Anything behind the front cover: gas valves and gas pressure, igniters and flame rods, temperature sensors, fans, circuit boards, heat exchangers, and venting changes. Overheat codes in particular should not be reset repeatedly; Rinnai says to treat its code 14 seriously[1].
When to call a pro
- The same code returns after one reset.
- Any overheat, gas valve, sensor, fan or board code.
- A vent code that returns after the outside terminals are clear.
- A gas type mismatch code after an install or conversion (Navien E773 or E788[2]).
More questions
Will resetting the unit clear the problem?
It clears the display, not the cause. One power cycle is a fair test for a passing glitch. If the same code returns, the unit is protecting itself and needs diagnosis.
Are these the manufacturers' own words?
No. We paraphrase each code in plain language from the maker's service document and link that document so you can check it. Your unit's own manual is the final word for your model.
Sources
- Troubleshooting Tankless Water Heater Diagnostic Codes (document 100000652), Rinnai America. Accessed 2026-10-06.
- NPE-2 User's Information Manual (2020-12), Navien. Accessed 2026-10-06.
- Tankless Gas Troubleshooting Pocket Manual SVC820, Rheem Manufacturing. Accessed 2026-10-06.
- What to do if you smell natural gas, CenterPoint Energy. Accessed 2026-10-06.
Water Heater Facts is an independent information service. We may be paid by contractors when we connect a homeowner with one; that never changes what we publish. Found an error? Tell us. We review safety and legal reports within 2 business days and all others within 7 days.